Decide which solids result you mean
Slurry density and percentage solids answer different questions. Density describes mass per unit volume of the mixture. A solids percentage describes a proportion, and that proportion can be expressed by mass or by volume. A useful plant trend needs to make that distinction explicit.
Our slurry density and percentage-solids calculator provides an illustration for a two-component mixture when the liquid and solids densities are known. It is a calculation model, not an independent measurement of those component properties.
The same mixture can have two different percentages
Consider an illustrative mixture with slurry density 1,350 kg/m³, liquid density 1,000 kg/m³ and solids density 2,650 kg/m³. These are assumed inputs for the example, rather than a specification for every mineral slurry.
Under a simple additive-volume, two-phase model, the solids volume fraction is (1,350 − 1,000) ÷ (2,650 − 1,000), giving approximately 21.21% solids by volume. Multiplying that fraction by solids density and dividing by slurry density gives approximately 41.64% solids by mass.
Both percentages describe the same assumed mixture. Neither should be compared directly with an operating target labelled only “% solids” until its basis is known.
Check the assumptions before using a conversion
The calculation depends on the component densities being suitable for the mixture being assessed. A change in mineral composition, a different liquid phase or a mixture that does not fit the two-phase model can make the earlier assumptions unsuitable. Entrained gas is an additional phase, rather than simply another solids percentage.
Record where the component-density inputs came from, their units and the conditions they represent. Keep a calculated result distinct from a laboratory result and from a directly configured instrument output. This makes later comparisons easier to interpret.
Connect the result to the actual process
A density trend can be useful without every operating decision being expressed as a calculated solids percentage. Start with the decision the operator needs to make, then agree the quantity and reference method that support it. See our guidance on thickener underflow measurement and hydrocyclone feed monitoring for process context.
If the basis of an existing plant target is unclear, discuss the measurement task with PMA before adopting a conversion. PMA's article on aggregate wash-plant density checks also explains why the application and the supporting reference evidence belong in the same conversation.